With the continuous development of the industrial and commercial fields, the straight-cooled block ice machine as an advanced and efficient refrigeration equipment has brought significant convenience and benefits to all walks of life. BOLANG explains the requirements for its use below.

Power requirements: The direct-cooled block ice machine needs to be connected to 220V power supply. Ensure that the power supply is stable and meets the rated voltage of the device.

图片1

Water requirements: Directly cooled block ice machine needs to access tap water or purify water, water quality requirements are high, it is best to use pure water, so as not to affect the quality of ice.

Environmental requirements: The direct-cooled block ice machine needs to be placed in a place with good ventilation and appropriate temperature to avoid direct sunlight, high temperature, humidity and other environment affecting the ice making effect.

Operation requirements: Before using the directly cooled block ice machine, it is necessary to read the equipment manual carefully and be familiar with the operation method and maintenance points of the equipment. When operating, follow the instructions, do not change the equipment Settings at will, so as not to affect the ice making effect.

Maintenance requirements: Regularly check the inlet and outlet pipe joints of the direct-cooled block ice machine in order to deal with a small amount of residual water that may leak; When ice making and crushed ice are not used, drain the remaining water in the inner tank and dry the inner tank with a clean cloth; The straight ice machine drain pipe should be checked once or twice a year to prevent blockage.

Installation requirements: Choose a suitable installation location, should be away from heat and direct sunlight, keep good ventilation; Installation should be smooth, avoid shaking and tilt; When installing, ensure the safety of the power line to avoid aging and short circuit of the wire.

图片3

Note: When the compressor is stopped for any reason (water shortage, excessive icing, power failure, etc.), it should not be started continuously, and it should be started every 5 minutes to avoid damage to the compressor; When the ambient temperature is lower than 0 ° C, ice may form. In this case, drain water. Otherwise, the water inlet pipe may break. When cleaning and checking the ice machine, unplug the power plug and do not use it for more than a week.

The above information is for reference only, the specific requirements and precautions should refer to the product manual or consult BOLANG refrigeration professionals